Control Tower 19 is the best pr interlocking plants remaining in Dallas and Tarrant counties. The tower and two one- story sheds are built in the Craftsman style, and comprise a complex which is representative of standardized service buildings which were constructed by the Atchison, Topeka, & Santa Fe Railroad (AT&SF) as well as other carriers west of the Mississippi. These buildings represent typical plan types which were generated by AT&SF company engineers and constructed by company crews along local and branch lines within the carrier's service area.
Built with greater variation than the standard plans for stations and depots, interlocking plants were constructed to control the increasing rail traffic along the company's routes through Dallas and other major transfer hubs during the early twentieth century. The building of Control Tower 19 in coincided with a major reconstruction program which AT&SF undertook in the throughout its service area. Constructed initially with a manual interlocking system to work in tandem with a second plant (Control Tower Control Tower 19 was retrofitted in with the more reliable electric interlocking system, supplied by the General Railway Signal Company of Rochester, New York.
This consolidated the switching functions of both towers into one, and allowed AT&SF to raze Control Tower 10, thereby reducing its labor and maintenance costs. Control Tower 19 remained in service until after Santa Fe Railway sold this section of its Dallas subdivision to the Dallas Area Rapid Transit System (DART) in . .- &*-Aw"i '&flfei.jJ?_' ATCHISON, TOPEKA, & SANTA FE CONTROL TOWER 19 HAER NO. Page 2 PART I. HISTORICAL INFORMATION A. Physical History 1. Date of Erection: 2. Architect: AT&SF company engineers 3. Original and Subsequent Owners: Atchison, Topeka & Santa Fe Railroad Dallas Area Rapid Transit (DART) System (1991-present) 4. Builders. Contractors and Suppliers: The interlocking plant and associated buildings were built by AT&SF company crews.
The manual interlocking system was provided* by an unknown company and was removed in when the General Railway Signal Company of Rochester, New York supplied and installed the electric interlocking system. 5. Original Plans and Construction: No original architectural plans or drawings were located during the research investigations. 6. Alterations and Additions: The interlocking plant and associated buildings have been slightly altered at unspecified times during the twentieth century. B. Historical Context: Control Tower 19 and its support buildings were constructed in by the Atchison, Topeka, & Santa Fe Railroad (AT&SF) at the instigation of the Houston & Texas Central Railroad to control the increasing rail traffic along AT&SF routes through Dallas[l].
Dallas had become a major transfer hub by and the building of Tower No. 19 coincided with a reconstruction program undertaken by the AT&SF during the in that city as well as in Chicago and Los Angeles. Control Tower 19 was constructed to work in tandem with Control Tower 10, an earlier manual interlocking plant which began service in Control Tower 10 was located at milepost 52, 1.0 miles to the southwest, and the operation of two towers allowed for a more efficient handling of rail traffic. Control Tower 19 is exemplary of the building design policy of AT&SF as well as other western carriers in utilizing essentially plain, functional designs, which could be inexpensively modified for each locale by making simple changes in plan or exterior detailing.
This reflected the growing standardization of American architecture and the increasing popularity of local architectural styles. AT&SF standard plans eventually would bear a significant resemblance to the designs of the Burlington Route, Great Northern, and several other western lines[2]. Control Tower 19 and the two service sheds were built in the Craftsman style and are representative of typical plan types which were generated by AT&SF company engineers and constructed by company crews. AT&SF interlocking plants were built with greater variation V, * f - . &A:J>Ji,&&')iLJ^*^ ATCHISON, TOPEKA, & SANTA FE CONTROL TOWER 19 HAER NO.
Page 3 than the standard plans for stations and depots, partly due to the program requirements associated with manual and electric interlocking systems, and depending upon the date of construction and the interlocking system used, plants differed in plan as well as building height[3]. Despite the increase in infrastructure development, AT&SF maintained a policy of reducing labor and maintenance costs, whenever possible. The installation of the General Railway Signal Company interlocking system in Control Tower 19 in while further enhancing the efficiency in controlling increased rail traffic, was viewed as an opportunity to concomitantly reduce expenditures.
As a result, Control Tower 10 was razed, after the switches of both towers were consolidated into Control Tower The new system provided however, a significant technological advancement over manual interlocking capabilities. The electric interlocking system, with its illuminated track diagram, allowed towers to be located at greater distances from the switches and signals they operated. Use of the manual interlocking system required the tower operator to be able to see tracks, trains, switches and signals, and it was standard practice to locate towers no more than seven or eight hundred feet from the farthest switch or signal. The interlocking system allowed these distances to be significantly increased, from between one and six thousand feet[5].
The system consisted of a power source provided by storage batteries and a generator, power control apparatus or relays introduced between the power source and interlocking machine, an interlocking machine with levers for the operation of switch and signal mechanisms, switch and signal mechanisms with operating and indicating circuits, and a control mechanism for the prevention of the unauthorized movement of any fiinction[6]. The advantages of this new system were touted by in its Electric Interlocking Handbook and became the choice of carriers such as AT&SF in their expansion programs throughout the West[6].
The operators of Control Tower 19 switched from between 65 to 100 trains daily for carriers such as: Gulf, Colorado, & Santa Fe; Union Terminal; Missouri-Kansas-Texas of Texas; Trinity & Brazos Valley; St. Louis, San Francisco & Texas; Chicago, Rock Island, & Gulf; St. Louis, Southwestern of Texas; and Houston & Texas Central. The plant remained in service from to In in an effort to divest itself of all north-south routes and concentrate only on transcontinental service, Santa Fe Railway sold the Texas main and local lines to Burlington Northern as well as this section of the Dallas subdivision to the Dallas Area Rapid Transit system, and abandoned the structures for their relocation and preservation at a local railroad museum.
There was an absence of extant records in the Santa Fe Railway archives for Control Tower 19. This was indicated as being a common occurrence by Santa Fe archivists in Topeka, '.2~i&J.j*&^J&a*. '; ... & -&i&i.< lutfti'Mfeji:-1 ATCHISON, TOPEKA, & SANTA FE CONTROL TOWER 19 HAER NO. Page 4 Kansas, Chicago, Illinois and Houston, Texas. The carrier's employees had a practice of regularly purging company documents and the lack of even maintenance records and as-built plans for Tower No. 19 was probably a result of that activity[8]. PART II. ARCHITECTURAL STATEMENT: A.
General Statement: Located at milepost 51 at the cross-over of the Santa Fe and Union Pacific Railway Lines, Control Tower 19 and its associated buildings comprise an intact early twentieth century railroad site, which features buildings that have been in continuous use until the late twentieth century. The tower faces northeast and is oriented perpendicular to the Santa Fe line and parallel to the Union Pacific line. The site is located in an industrial district of Dallas, south of the central business district, and is approached from the southeast by a gravel drive. The site includes a three-story interlocking plant, HAER No. a one-story maintenance shed, HAER No. TX-22-A; and a one-story tool shed, HAER No.
The site is not landscaped and the right-of-way is cleared and covered in gravel. An thick concrete wall, which was built to protect the tower and its support buildings from potential high water from floods, which the site is susceptible to, is located on the west side of the buildings, and is oriented northeast-southwest. Another thick wing wall, oriented in a north-south direction, protects the south side of the tower. 1. History: Control Tower 19 was built in and furnished with a manual interlocking system, and later retrofitted with an electric system in Four ground floor window openings were replaced with metal louvers and enclosed with wood siding ca.
Two second floor window openings on the north as well as the south and east sides of the building were enclosed and covered in wood siding ca The original stair was removed and replaced ca. and some equipment modifications were made at unspecified times during the twentieth century. 2. Architectural Character: The tower is a three-story interlocking plant with a wood stair located at the south side of the building. (See photographic documentation, HAER No. through HAER No. and HAER drawings, Sheets B. Description of Exterior: 1. Overall Dimensions: The building measures in width and in depth. 2. Foundations: The foundation is a raised slab of poured-in-place, board-formed concrete. ^^' - ATCHISON, TOPEKA, & SANTA FE CONTROL TOWER 19 HAER NO. Page 5 3.
Wall Construction: Exterior walls at the ground floor vary in thickness from to 10- and are of board-formed concrete. Interior wall surfaces feature horizontal formwork impressions, in width, while exterior surfaces are smooth-finished. Wall thickness at the second and third floors averages at 7" in thickness, and the walls are covered in wood drop siding, thick with a exposure. The tower is trimmed at the corners with 1" x 6" corner boards, which terminate into a 6" frieze board. 4. Structural System. Framing: The second and third floors of the tower are of balloon frame construction, using circular-sawn, 2" thick members. Floor joists are nominal-sized 2" x ceiling joists are 2" x 6", with a single 2" x 8" laid northeast-southwest, at mid- span.
Rafters are circular-sawn x and are supported by a ridge rafter of equal dimension. 5. Chimneys: None. Stove pipes for open gas heaters are located on the second and third floors. 6. Openings: a. Doorways and Doors: Original doors are four or glazed five-panel and measure x and x respectively. A pair of vertical board service doors, measuring x are suspended from an overhead track and provide access to a cable termination room on the ground floor. A glazed, solid core wood door has replaced the original panelled entry door to the switching equipment room and measures x The heads and jambs are simply cased in 1" thick wood trim, with widths varying from 5" to Door jambs and heads in the concrete walls at the first floor are finished with 1" chamfers. b.
Windows: Original windows at the first floor were two-light, horizontal metal casements which have been removed for the installation of metal vents or covered over with wood siding. Original windows at the second floor have been removed and the openings enclosed with wood siding, and were probably similar to the third floor units. Windows at the third floor are single-hung, one-over-one wood sash, varying in width from to and are in height. The heads and jambs are cased in 1" thick wood trim, with 8" or 10" widths. The heads include crown molding, with a tapered 2"x used as a drip cap, and a double wood sill, trimmed at the base with a continuous horizontal molding. 7. Roof: a. Shape.
Covering: The roof is hipped with a slope of 7 in 12 and is covered in composition shingles over dutch tab asbestos shingles. b. Cornice: The soffit is open and features exposed x tongue and groove,roof decking, supported on wood rafters with scroll-sawn decorative tails and arched brackets that interrupt a x cornice mold. "2..i jd_'*.Lirf*--Ji^a - ATCHISON, TOPEKA, & SANTA FE CONTROL TOWER 19 HAER NO. Page 6 C. Description of Interior: 1. Floor Plans: a. First Floor: The first floor is divided by a concrete partition wall into two rooms which are entered through two separate doors. The east room is the cable termination room and also serves as ancillary storage. The west room is the battery room. b.
Second Floor: The second floor is divided by a wood frame partition into a corridor, oriented east-west which also serves as a restroom, and a large relay equipment room. c. Third Floor: The third floor is open and serves as the switching equipment room. 2. Flooring: The first and second floors are smooth-finished, 8" concrete slabs. The third floor is covered in x tongue and groove, laid northwest-southeast, and painted. 3. Wall and Ceiling Finish: Interior wall thickness at the first floor is 8" 4. Doorways and Doors: A single four-panel interior door, measuring x is located at the second floor and provides access from the corridor/toilet to the relay equipment room. 5. Decorative Features: None. 6. Lighting Fixtures: Light fixtures are ca. ceiling-mounted incandescents and flourescents.
7. Heating: The first and second floors are unheated. An open gas and an electric heater provide heat for the third floor. Window units provide air-conditioning for the third floor. 8. Equipment: a. First Floor: The cable termination room includes a wooden cabinet or cable termination box which houses cables which are connected from the battery room and fed through a chase in the ceiling to relay racks on the floor above. Two battery racks are located in the battery room to generate power for the operation of the interlocking machine. b. Second Floor: The relay equipment room houses relay racks and a radio transmission power booster.
c Third Floor: The interlocking machine is located on the switching equipment room floor and includes two illuminated track diagrams and a direct current ampmeter. A power terminal is located in the northeast corner of the room and an operator's desk, radio and a central traffic control board are positioned in the southeast corner. Mi:Sf-i^Ci> ^*e".iBmtfLL:.-'a,jSi ATCHISON, TOPEKA, & SANTA FE CONTROL TOWER 19 HAER NO. Page 7