BlockBefore

Fire Station No. 28, 644 South Figueroa Street, Los Angeles

Fire Station No. 28, 644 South Figueroa Street, Los Angeles, Los Angeles County, CA. Surveyed as HABS CAL,19-LOSAN,61-, with a 1,358-word written history.

From the record

“The building is one of the first reinforced concrete fire stations in Los Ajigeles.”

Written record, HABS CAL,19-LOSAN,61- survey. Machine-read text.

Surveyed by the federal HABS program as HABS CAL,19-LOSAN,61- · the record runs 1358 words · one of 386 surveyed structures published for this county.

Sources: the survey record at the Library of Congress

Significance

1066 words

Source document Quoted word for word from HABS CAL,19-LOSAN,61-. Not written, edited or summarised by this site.

The building is one of the first reinforced concrete fire stations in Los Ajigeles. It was a Class A fire- proof structure built of brick, hollow tile and concrete. Its original cost was The building is an interesting and unusual design. In relation to the surrounding buildings, Fire Station 28 provides a re- freshing reduction of scale and serves as a historic monument to the growth of Los Angeles. PART I." HISTORICAL INFORMATION A. Physical History 1. Date of Erection: (City of Los Angeles, building permits) 2. Architect: J. P. Krempel and W. E. Erkes John Krempel and Walter Erkes - The partnership produced a number of structures throughout Southern California over a twenty-year period.

The firm de- signed the second Times Mirror Company In the home of General Otis, Santa Barbara High School, and the Maier-Brewery Company buildings, to name but a few. Krempel was one of the earliest architects in Los Angeles. He arrived in Southern California during the mid-1880's. In he established his own office, working alone until when he joined with Erkes in partnership. Fire Station 28 is one of the first buildings designed by the firm. The two men worked successfully together until Krempel's death in Fire Station No. 2 HABS NO. CA-2155 Page 2 3. Original and Subsequent Owners: 190 8 Acquisition Deed No. recorded December 1, in Book page 5 James A. Brown, Blanche Brown, Elon W. Bramble, and Loraine Bramble to the City of Los Angeles 4. Builder: Kubach and Company 5.

Original Plans and Construction: Not located 6. Alterations and Additions: Alterations are minor; most have occurred on the interior. A few small windows on the sides of the building have.been filled in. Historical Context: At the time Fire Station 28 was built on what was then Pearl Street, there was little commercial development in that area of town. The fire station must have been built to serve the needs of the residential and agricultural development stretching froiri Pearl Street through what is now mid-Wilshire. The two entrance bays were designed for use by horse drawn engines. The building included an apartment for the fire captain and his family, a dorm for the firemen , and recreation rooms for the firefighters.

The limited size of the door bays and the general smallness of the station have made it unworkable for modern fire- fighting equipment. Fire Station No. 2 HABS NO. CA-2155 Psqo 3 PART II. ARCHITECTURAL INFORMATION A. General Statement: 1. Architectural Character: This fireproof structure consists of a three story building with a basement. Major architectural features include twin parapet towers with inset arches and capped by flagpoles. The windows are contained within two story arched bays. The building has windows with pilaster and entablature surrounds. The two central doorways are recessed and framed by brackets. The structure is built on a rectangular plan with two symmetrically placed entrance bays.

The wall surface has two large arched and recessed panels with both flat and arched window openings. The brickwork is set in unusual arched patterns. Three stone shields are spaced evenly across the facade above the second story. The eclectic architectural style is influenced by classical references with bracketed cornices. The facade is intact. Alterations are confined to the interior, with the exception of the filling in of several small window openings on the sides of the building, 2. Condition of Faerie: Good B. Exterior Description: 1. Over-all Dimensions: The structure is located on a lot of acres. The frontage is 50' and the depth is 2. Foundations: The foundations are of brick and reinforced concrete. 3.

Walls: The walls are of brick construction and are, with the exception of the entrance facade, devoid of decorative detail. The entrance facade consists of a flat wall surface articulated by a double main entrance, inset bays, applied decoration and a bracketed cornice. 4. Structural System, Framing: The structure is of fire- proof brick construction with some reinforced concrete. 5. Porches, Stoops, Balconies, Bulkheads: none 6. Chimneys: A small chimney is located in the southwest corner of the structure at the roof'l Fire Station No. 28 HABS NO. CA-2155 Page 4 7. Openings: a. Doorways and Doors: There are two symmetrical _ main entrances flanking a central brick pier. The doorway configuration is flat and the doors are of wood and metal construction.

Additional recess is provided by a door offset to the north of the major entrance bays. b. Windows and Shutters: The wall surface is relieved by two large arched and recessed panels. Set into these panels are windows with both arched and flat surrounds and pilasters attached to the wall surface. The windows are of the sash type. 8. Roof: a. Shape, Covering: The roof is flat in configuration and is of composite construction. b. Cornice, Eaves: A bracketed cornice is set between two parapet towers. c. Dormers, Cupolas, Towers: Twin parapet towers flank a parapet cornice. The towers are of brick construction and have pyramidal red tile roofs. C.

Description of the Interior: Since this submission refers only to exterior recordation of the structure, only a brief description of interior details is included. The building is designed to accommodate equipment on the lower level with living quarters above. There are, however, relatively few wall partitions on the upper stories. D. Site: 1. General Setting and Orientation: The structure fronts on Figueroa Street and is oriented on an east to west axis. The structure is entered from the west on Figueroa The building is located in a densely built urban environ- ment and is surrounded by structures of an incompatible size, design, and scale. 2. Historic Landscape Design: none 3. Outbuildings: none a/ Fire St Page 5 313 * ' f . - , .,; " " ' -ir j- - - - - - X *M ' T J ; -t* : ; "> 1 'j.

" *"* r - - _ ^ z v J ,-; * " ^ * * , .V! ': _ -~ - i-'i"" =V_ V-^-i ,- -* < Fire Station No. 28 HABS NO. CA-2155 Page 6 PART III. SOURCES OF INFORMATION A. Bibliography 1. Primary and unpublished sources: City of Los Angeles, Department of Building and Safety, building permits City of Los Angeles, Department of Planning, Land Use Planning and Management System County of Los Angeles, Recorder's Office, Official Records of the County of Los Angeles 2. Secondary

Sources

187 words

Source document Quoted word for word from HABS CAL,19-LOSAN,61-. Not written, edited or summarised by this site.

Baists Real Estate Atlas of Los Angeles (G. W. Baist Co., Philadelphia, Pa.: Hatheway, Roger G., "Historic Building Survey: Request for Determination of Eligibility" (Los Angeles Downtown People Mover Program: January, Los Angeles Times, April 16, VI, 3. Sanborn Map Company, Los Angeles Fire Insurance Maps (New York: Works Projects Administration, Los Angeles Drawings (Los Angeles, Fire Station No. 2: HABS NO. CA-2155 Page 7 Prepared by: Myra L. Frank, Senior Transportation Planne: Roger G. Hatheway, Consulting Research Historian Los Ang e1e s Down town People Mover Authority October, PART IV.

PROJECT INFORMATION The Los Angeles Downtown People Mover Project, supported by a demonstrated grant from the Urban Mass Transportation Admini- stration, is proposing to build an automated, grade-separated transit system in downtown Los Angeles. A portion of the route as proposed would run along a median in the middle of Figueroa Street, approximately 30 feet from the facade of the Fire Station. Locating the DPM in the center of the street will not require alterations to the structure, but will create a new visual element of front of the structure as viewed from across the street.

In context

Los Angeles, California The place record: every map, photograph and survey of this town.
Los Angeles County, California 1,078 topographic sheets across the county.
Library of Congress record The original filed report as the survey filed it.

Also surveyed in Los Angeles

24 of 142 records shown

The federal surveyors worked through Los Angeles building by building. These are the other structures they measured and filed a report on, longest report first.

SheetStructure SurveyReport
Los Angeles River BridgesHAER CA-27121,165 words
Los Angeles Music CenterHABS CA-278018,683 words
Lytton Savings and Loan AssociationHABS CA-293616,955 words
Eames HouseHABS CA-290316,265 words
Times Mirror Building and Parking StructureHABS CA-293514,277 words
Los Angeles City HallHABS CAL,19-LOSAN,51-9,036 words
Crossroads of the WorldHABS CA-29658,968 words
Vickrey-Brunswig BuildingHABS CA-27988,766 words
Plaza HouseHABS CA-27998,766 words
Golden Gate TheaterHABS CA-28798,348 words
Holiday BowlHABS CA-27758,280 words
Westlake School for GirlsHABS CA-27918,007 words
Morris Landau HouseHABS CA-27897,644 words
The Hollywood Reporter BuildingHABS CA-29597,302 words
Olive Switching StationHABS CAL,19-LOSAN,80-7,190 words
El AlisalHABS CAL,19-LOSAN,15-6,775 words
Parker CenterHABS CA-29236,594 words
First Street Viaduct over Glendale BoulevardHAER CA-23436,577 words
Brunswig AnnexHABS CA-27936,453 words
University of California Los AngelesHABS CA-2678-A5,023 words
California Teachers Association Building No. 1HABS CA-29604,425 words
Hollyhock HouseHABS CAL,19-LOSAN,28-4,248 words
Rancho La Brea AdobeHABS CAL,19-LOSAN,26-4,227 words
Bullinger BuildingHABS CA-29644,042 words

Provenance

  • Written history. Quoted verbatim from HABS CAL,19-LOSAN,61-. United States federal work, no copyright under 17 U.S.C. 105.
  • Text capture. Machine-read from the scanned typescript filed with the survey, so spelling and spacing follow the original page.
  • How this page is made. Documentary passages are quoted from the linked federal record; page labels and counts are clearly marked as site presentation or calculations.