Engineered by the U.S. Army Corps of Engineers, Jacksonville Office in Moore Haven Lock was designed for preventive measures during hurricanes, floods, and droughts while allowing navigation on the Okeechobee Intracoastal Waterway, a 155-mile passage connecting the Gulf of Mexico with the Atlantic Ocean via Lake Okeechobee. Report Prepared by: David E. Port and Dena E. Hodes, New South Associates Date: December MOORE HAVEN LOCK, HURRICANE GATE NO. 1 HAER NO. FL-18-A Page 2 PART I. HISTORICAL INFORMATION A. Physical History: 1. Date of Construction: 2. Architect/Engineer: U.S. Engineer Office, Jacksonville, Florida, War Department 3. Original and Subsequent Owners: State of Florida, U.S. Army Corps of Engineers 4. Original Builder: Edgar H. Latham Construction Company of Miami, Florida 5.
Alterations and Additions: The original timber bumpers along the interior of the lock chamber were replaced with steel sheet pile in B. Historical Context Moore Haven Lock was constructed in by the U.S. Army Corps of Engineers to assist in flood control and enable navigation on the Caloosahatchee River and the Cross-State Canal. This structure also serves as Hurricane Gate No. 1 in the Lake Okeechobee levee system to protect the town of Moore Haven and surrounding areas from catastrophic floods during storms. This is second lock constructed at Moore Haven. The first was built in and located adjacent to the town's business district on the south bank of the Three-Mile Canal. PART II. DESCRIPTION A.
General Statement The Moore Haven Lock is situated on an 8-acre reservation on the southwestern shore of Lake Okeechobee at the confluence of the Caloosahatchee River. It is located just behind the levee that projects the adjacent city of Moore Haven from floods. The lock serves the purpose of navigation while the connecting spillway, located east of the lock, is operated for flood control, irrigation, maintenance of water stages during low-flow periods and water conservation during droughts. MOORE HAVEN LOCK, HURRICANE GATE NO. 1 HAER NO. FL-18-A Page 3 The lock is long and 50' wide and constructed of concrete lined with steel sheet pile. The gates are steel and the larger, upper lock gates serve as Hurricane Gate No. 1 in the Okeechobee levee system.
There is one control house located on top of the levee just north of the lock that houses the operating equipment for the gates. The concrete spillway was constructed in and is located in the levee east of the lock. It has four bays consists of four vertical or slide gates. There are two lock tender's houses set on the west bank of the river along with a garage, fire pump house, warehouse, and generator house. Also included on the reservation is a maintenance depot slip that is located on the western, downstream side of the lock. B. Physical Description Moore Haven Lock The lock's measures approximately in length, 50' in width, and in depth or below mean sea level with a lift averaging 1' to 5' depending upon the water level.
The Moore Haven facility was built-up, landscaped and graded to an average height of above mean sea level (AMSL). However, the highest elevation for this facility is the levee directly to the north, which is AMSL. Considering Moore Haven's history and the hurricane's damage, the facility was designed to be a functional bulwark against other hurricanes and tidal waves. On the uplake side, the lake's bottom or entrance sill to the lock chamber is This elevation decreases to on the Caloosahatchee River's side as part of the natural grade and release of the water downstream.
From the surface level along the lock chamber, the total depth of the chamber is This depth permits unrestricted transit between the upper and lower pools even during times when the minimum water level of the upper pool is 10' AMSL. On the uplake side, the masonry portion of this structure serves a dual purpose of supporting the hurricane sector gate and its load and of retaining the levee embankment from the canal opening. The canal prism or entranceway through the levee has a 50' clear opening with the levee crown elevation extending to MOORE HAVEN LOCK, HURRICANE GATE NO. 1 HAER NO. FL-18-A Page 4 The Moore Haven is equipped with a maintenance depot slip that is located on the westerly downstream side of the lock.
The slip is approximately in length and in width and with a bottom elevation of AMSL. The small harbor originally included a boat house (non-extant) and a dock x 8' that had four open docking bays for small craft. The docks remain. The face of the concrete lock chamber walls and the channel side of sector gates were protected with creosote timber bumpers, but in June the timber fenders were replaced with steel sheet pile and the recesses were in-filled with concrete. The chamber contains eight needle dam girder recesses or sills. There are four on each side of the chamber with two sills in front of and two behind each of the lock sector gates.
These recesses measure in width and hold the needle dam girders, which are essentially used to support the temporary dams that are used during dewatering for the repair and maintenance of the inner lock chamber. The floor of the lock chamber is a length of steel sheet pile wall laid on top of a 6' poured reinforced concrete foundation, which is set on a network of timber pilings. The massive housing for the hurricane gate consists entirely of reinforced concrete, exceeding an elevation of and makes up one-third of the concrete used for the entire lock chamber. Upper and Lower Gate Structures The upper lock gate structure on the uplake side is provided with a hurricane sector gate consisting of two 60 , radius structural steel sectors high on the perimeter face.
The lower lock gate structure has a sector gate consisting of two 60 , radius structural steel sectors high on the perimeter face. The size and the weight of the gates are relative to their position where the upper gate is the larger and thus can withstand more pressure against its mass. All sector gates are swung from the top by a single hinge and supported at the bottom by a pintle. The lock gates appear in design and form to resemble large taintor-type gates laid on their side with additional steel buttressing. Electrically driven reduction gears prescribe movement. The gates move into arced-shaped housings set into the lock sides to provide MOORE HAVEN LOCK, HURRICANE GATE NO. 1 HAER NO. FL-18-A Page 5 unobtrusive boat transit.
The gate assemblies may be accessible by manholes set back from the top of the lock covered by grating, and vertically by climbing down onto the gates when locked into place. The upper gate housing is constructed or poured reinforced concrete. During hurricane storm tides, the hurricane gates can be locked in place. The lock gates have moveable catwalks at both ends of the chamber that transverses the vault. The catwalks are on top of each sector gate and form a V-shaped pattern when closed. These catwalks over the lock gate allow access to the opposite side of the lock chamber. They move accordingly to the opening and closing of the lock sector gates. The upper and lower gates at Moore Haven are operated from the control house on the north side of the chamber on top of the levee.
It contain all of the remote control and drum type control switches, indicator lights, differential, water level indicators, gate position indicators, emergency stop switch and water level by-pass switches. Interior of the Lock Chamber and Mechanical Equipment The lock structure consists of four sector gates operated by cable drum units. The motor units for operating each of the four sector gates are located in the machinery recesses, or covered below surface areas, within the lock chamber wall, while the gear boxes are located within the arced-shaped housing wells set into the lock chamber's sides for each sector gate.
A channel guide is installed around the outside face of each sector gate and movement of the gate is effected by cable stretched around the outside surface in the channel guide through sheaves and idlers to cable drums. The cable drums for movement of gate are powered by electric motors through a system of gears and speed reducing units. The operation of two motors is needed to move the sector gates in tandem, or one half of the lock gate. The units are normally operated electrically, but emergency provisions are made on each unit for operation with a manual miter crank. The AC motors function through a system of speed-reducing gears, which also power the cable drums for movement of the gates, and are engaged through a manually operated clutch. MOORE HAVEN LOCK, HURRICANE GATE NO.
1 HAER NO. FL-18-A Page 6 The speed reducer units consist of a worm-gear speed-reducer of the horizontal type direct-connected to the cable drum and a spur gear speed-reducer unit direct-connected to an electric motor by flexible coupling. The worm-gear units are 5 with an overall ratio of 20 to 1. The units are equipped with a lubrication system, an oil level indicator and oil drain. A hand hole for inspection of the gears is provided in the case. It is capable of withstanding an overload of 100 percent of full load torque for starting and stopping duty. The spur gear units are rated 5 with an input shaft speed of revolutions per minute with an overall ratio of to 1. The speed- reducer units are housed in the machinery recesses.
The hand drive units are vertical drive, worm gear speed reducing and are mounted above the machinery recesses on top of the lock structure. The overall ratio is to 1. The units are assembled with an engagement and disengagement device from the hand-drive unit to the gate operating machinery. The following information details the motors and their components within the machinery recesses and sector gates: The motors are totally enclosed, fan cooled of splash and waterproof construction, high-torque, high-slip, and double squirrel cage induction type for across-the-line starting. They are rated 5 220-volt, 3-phase, 60-cycle, and are located in the machinery recesses. The brakes for stopping each sector gate are mounted on the extended shaft on each sector gate motor.
The brakes are spring-set, disc type, with magnetic operated releases. Right angle drive gear units contain the spur, angle and pinion gears assembled in a cast-iron housing and are connected from the speed reducer unit in the machinery houses to the rack gears on each sector gate. The unit is equipped with a grease lubrication system. A hand hole is provided for inspection of the gears. The magnetic contactors are reversing magnetic, full-voltage-starting, shunt type. The contact tips are removable, faced with a non-welding alloy and are connected to the terminal studs with flexible copper leads. They are remotely controlled by the push button station switches and are located in the control house. They are used to control the gate motors.
Limit switches are of the lever, spring return type actuated by cams located at either end of the sector gate and geared to the gate operating machinery. The unit consists of a totally enclosed submersible cast-iron case with switch elements arranged in sequence MOORE HAVEN LOCK, HURRICANE GATE NO. 1 HAER NO. FL-18-A Page 7 for the proper function of the sector gates. The limit switches are manufactured by Cutler-Hammer, Inc. Transmitters consist of two selsyn transmitters, one of which is geared directly to the gate operating machinery and serves the purpose of indicating the position of the gates. The other one is connected to a ball float, steel tape and weight in the gauge wall and serves the purpose of indicating water level.
The push button start switches are located in the control house and are used to control the magnetic reversing switches that activate the electric motors for the sector gates. The push button station consists of three switch elements: Open, Close, and Stop. 1 The lock is equipped with traffic control lights and horns, mooring bits, and standard safety equipment to allow efficient and safe passage. The lock chamber has a water level table register located on both sides of the chamber to allow visual tracking of the water level. The operation hours at all of the locks are from AM to PM year round with the last lockage performed at PM. The locks are opened upon demand and all lock-throughs are free of charge.
During a severe drought like the one in the summer the lock was only opened every two hours. In approximately vessels, not including Corps' dredges and boats, used Moore Haven's Lock even though it was closed for maintenance and dewatering from June to August. In the mid-1990s, manatee fences and electronic sensors were installed on the sector gates to allow manatees to lock themselves through. Screens were also installed on the spillways, which prohibited the passage of manatees and other large aquatic wildlife along this corridor. Electronic sensor beams monitor the opening and closing of the lock gates. If a manatee should pass through the gates and activates the sensors, an alarm sounds, red flashing lights go off, and the gates automatically stop, allowing the manatee safe passage.
Fish are also locked through the chamber, and during dewatering, the fish within the chamber are collected and released. Lock Channel A protective dolphin system, which resemble timbered tripods and act as protective fenders, is located on each side of the 1 Operation Manual: Moore Haven Lock, Department of the Army, Jacksonville District, Corps of Engineers, SAJP 16 November copy obtained from the Corps' South Florida Operations Office, Clewiston District, MOORE HAVEN LOCK, HURRICANE GATE NO. 1 HAER NO. FL-18-A Page 8 channel, approximately 25' from the upstream and downstream ends of the lock and fender system. A creosote pile fender system with catwalks extends above the lock on the northeast side of the channel and below the lock on the southwest side of the channel.
A series of seven tie-up dolphins is located upstream of the lock and on the north side of the Intracoastal Waterway near its intersection with the lock approach channel, while a similar system is located downstream of the lock on the west side. The bottom and side slopes of the approach channel are riprapped for a distance of 50' uplake and downstream, beyond the ends of the lock structure. The riprap extends across the channel downstream of the spillway within the same limits. The grouted riprap over the bottom area is 2' thick and all side slopes are riprapped to a thickness of 1' on a 1 to 1.5 percent slope. A safety barrier consisting of a series of creosote pilings, joined by metal I-beams that are supported by flotation material, is located immediately above the spillway. C.
General Siting and Orientation The lock complex is situated one-half mile north of the town of Moore Haven. The lock and dam lie across the channel in an east-west fashion. MOORE HAVEN LOCK, HURRICANE GATE NO. 1 HAER NO. FL-18-A Page 9 PART III. SOURCES OF INFORMATION A. Architectural Drawings The engineering drawings are located at the U.S. Corps of Engineers Office, South Florida Office, Clewiston District. They have been electronically scanned producing high-resolution images. The full collection of scanned images for Ortona Lock and Dam will be donated to the Florida State Archives, Tallahassee, Florida. B. Bibliography Operation Manual: Moore Haven Lock. Department of the Army, Jacksonville District, Corps of Engineers. SAJP 2.
16 November Copy obtained from the Corps' South Florida Operations Office, Clewiston District.