BlockBefore

Moore Haven Lock, Lock Control House, Cross-State Canal, Okeechobee Intracoastal Waterway, Moore Haven

Moore Haven Lock, Lock Control House, Cross-State Canal, Okeechobee Intracoastal Waterway, Moore Haven, Glades County, FL. Surveyed as HAER FL-18-B, with a 1,378-word written history.

From the record

“The control house is significant for its role in the operation of the lock gates.”

Written record, HAER FL-18-B survey. Machine-read text.

Surveyed by the federal HAER program as HAER FL-18-B · the record runs 1378 words · one of 18 surveyed structures published for this county.

Sources: the survey record at the Library of Congress

Significance

1264 words

Source document Quoted word for word from HAER FL-18-B. Not written, edited or summarised by this site.

The control house is significant for its role in the operation of the lock gates. Report Prepared by: David E. Port and Dena E. Hodes, New South Associates Date: December MOORE HAVEN LOCK, LOCK CONTROL HOUSE (Moore Haven Lock, Building No. SF 77) HAER NO. Page 2 PART I. HISTORICAL INFORMATION A. Physical History: 1. Date of Construction: 2. Architect/Engineer: U.S. Army Corps of Engineers, Jacksonville, Florida 3. Original and subsequent owners: State of Florida, U.S. Army Corps of Engineers 4. Original Builder: Spadaro Construction Company, Glades County, Florida 5. Alterations: In a rectangular concrete addition was added to the south elevation. B.

Historical Context The control house was constructed in to house the electrical and mechanical equipment used in the operation of the lock gates. It is set on top of the levee surrounding Lake Okeechobee to provide a clear view of boat traffic entering the channel. PART II. DESCRIPTION A. General Statement The control house is constructed of reinforced poured concrete and designed to house the electrical-mechanical motors to operate the lock gates. The original structure contained only one room, but a addition over doubled its size and added another room. The control house is set on top of the levee just to the north of the lock chamber and immediately adjacent to the upper lock gate. It has windows on all sides to allow for unrestricted view of the lock chamber and channel.

The building is utilitarian, almost Spartan in design, with no significant architectural detailing. MOORE HAVEN LOCK, LOCK CONTROL HOUSE (Moore Haven Lock, Building No. SF 77) HAER NO. Page 3 B. Physical Description 1. Exterior: a. General: The lock control house is one-story with a low- pitched pyramidal roof on the original section and a flat roof on the southern addition. It is constructed of reinforced concrete. The oldest section measures 10' x x and the new portion is x x b. Foundation: The control house rests on the concrete walkway platform that forms the hurricane gate structure. The west elevation of the control house is flush with the sloped buttressing of the hurricane gate structure. c. Walls: All of the walls are painted reinforced concrete. The corners are chamfered d.

Structural system: The house is built of reinforced concrete. The minimum distance from surface of the reinforcing bars to the surface of the concrete is e. Openings: 1. Doors: The lock control house has a single door on its east elevation immediately adjacent to the lock gate. It is probably a replacement steel door as it resembles the same doors at the Ortona Lock and Dam. The door measures x and has a centered one-light square window. As built drawings for Ortona's lock control houses show that the original doors were half-glass with four lights. 2. Windows: Facing north, the house features one fixed six-light window that measures x Facing the lock chamber, there are two-over-two sash single-hung windows measuring x flanking the central entrance door.

The control house addition has large, steel frame, pivot windows on all three sides. The eastern and western windows have nine-lights and measures x There is a similar six-light window located on south elevation, which measures x The arrangement of windows provides unrestricted views of the lake, chamber, and the Caloosahatchee River. Sliding, metal hurricane shutters have been added to all of the windows. MOORE HAVEN LOCK, LOCK CONTROL HOUSE (Moore Haven Lock, Building No. SF 77) HAER NO. Page 4 f. Roof: The original lock control house has a low, pyramidal roof of reinforced concrete with beveled trim under the open eaves' line and soffit. The addition features a 6" flat reinforced concrete roof with an exterior seam along the close rake cornice return.

The eastern elevation features a 4" concrete overhang. The house has two metal brown awnings over the door and north-facing window. 2. Interior: a. Floor plans: This building contains two rooms. b. Flooring: The flooring is reinforced poured concrete. c. Mechanical systems: Locking procedures are run entirely by the electrical control panels that faces the north approach and eastern interior wall. The control panel is best described as a flat upright enclosed, isometric console mounted on a steel cabinet and designed for the lock personnel to sit at and operate during locking procedures. The electrical panel permits both manual and automatic operations, and they also contain separate controls for each lock gate, bargraph readouts of gate positions and lock, and lake water levels.

The control panels are installed with the self-synchronous devices consisting of the four selsyn receivers that operate the differential water level and gate position indicators. The lock personnel also may control the lock approach and traffic control lights as well as the catwalk gate operation. Spadaro Construction Company originally installed the existing General Electric (GE) control panels in and all operations are still controlled through manual switches. The following information was recorded on one control panel housed in the control booth at Ortona The patent plate was verified through Schenectady Museum, which houses the largest archives of patented General Electric products.

The GE Patent Plate: The information underlined represents letters and numbers that are stamped inside a box. There was also a large 3 and a 5 to the left and the right of this plate. MOORE HAVEN LOCK, LOCK CONTROL HOUSE (Moore Haven Lock, Building No. SF 77) HAER NO. Page 5 GENERAL GE ELECTRIC CR 2 906 -Yl SERVICE CONTROL DESK HB 5 AMP 16 VOLTS 220 CYCLES 60 PHASE 3 CAT. CONN PP - Caution! Before installing or operating read inst. (Navy emblem and Swastika or Publication Index) Schenectady, Source: Patent Plate Text According to the archivist at Schenectady Museum, no records of Moore Haven Lock, the Cross-State Canal, Spadaro Construction Company, the War Department, and the Caloosahatchee River were found during an archival search.

The contractor probably did the actual installation, and therefore, GE left no record of it. The was a "generic" relay panel that was used for large motor or pump control. While GE does have many photographs of this panel, there are none from Florida. As for the swastika, the archivist concurred that it was related to a publication manual index. This symbol could have been any character that GE chose to utilize, and the swastika was used to illustrate that there was an "indefinitely out-of-print" user manual for this model during the late and early 1 It is only a coincidence that a swastika appears on one control panel during Moore Haven's construction and completion prior to World War II. C.

General Siting The Moore Haven lock control house is located on the west side of the lock chamber irrunediately adjacent to the upper lock gate. It is set on top of the levee and is accessed either by a flight 1 Chris Hunter (Schenectady Museum archivist), unrecorded interview with author, MOORE HAVEN LOCK, LOCK CONTROL HOUSE (Moore Haven Lock, Building No. SF 77) HAER NO. Page 6 of stairs located on the north and south sides of the hurricane gate housing or the parking area located on the top of the levee west of the house. The levee is planted with grass, but there is no other significant landscaping. PART III. SOURCES OF INFORMATION A. Architectural Drawings The engineering drawings are located at the U.S. Corps of Engineers Office, South Florida Office, Clewiston District.

They have been electronically scanned producing high-resolution images. The full collection of scanned images for Ortona Lock and Dam will be donated to the Florida State Archives, Tallahassee, Florida. B. Bibliography Hunter, Chris (Schenectady Museum archivist). Unrecorded interview with author.

In context

Moore Haven, Florida The place record: every map, photograph and survey of this town.
Glades County, Florida 47 topographic sheets across the county.
Library of Congress record The original filed report as the survey filed it.

Also surveyed in Moore Haven

9 records

The federal surveyors worked through Moore Haven building by building. These are the other structures they measured and filed a report on, longest report first.

SheetStructure SurveyReport
Moore Haven LockHAER FL-1811,189 words
Moore Haven LockHAER FL-18-A2,726 words
Moore Haven LockHAER FL-18-D2,480 words
Moore Haven LockHAER FL-18-C2,402 words
Moore Haven LockHAER FL-18-E1,911 words
Moore Haven LockHAER FL-18-I1,426 words
Moore Haven LockHAER FL-18-F966 words
Moore Haven LockHAER FL-18-G730 words
Moore Haven LockHAER FL-18-H473 words

Provenance

  • Written history. Quoted verbatim from HAER FL-18-B. United States federal work, no copyright under 17 U.S.C. 105.
  • Text capture. Machine-read from the scanned typescript filed with the survey, so spelling and spacing follow the original page.
  • How this page is made. Documentary passages are quoted from the linked federal record; page labels and counts are clearly marked as site presentation or calculations.