BlockBefore

Moore Haven Lock, Spillway, Cross-State Canal, Okeechobee Intracoastal Waterway, Moore Haven

Moore Haven Lock, Spillway, Cross-State Canal, Okeechobee Intracoastal Waterway, Moore Haven, Glades County, FL. Surveyed as HAER FL-18-I, with a 1,426-word written history.

From the record

“Army Corps of Engineers, Jacksonville Office in the Moore Haven Spillway was designed for preventive measures during hurricanes, floods, and droughts.”

Written record, HAER FL-18-I survey. Machine-read text.

Surveyed by the federal HAER program as HAER FL-18-I · the record runs 1426 words · one of 18 surveyed structures published for this county.

Sources: the survey record at the Library of Congress

Significance

1326 words

Source document Quoted word for word from HAER FL-18-I. Not written, edited or summarised by this site.

Engineered by the U.S. Army Corps of Engineers, Jacksonville Office in the Moore Haven Spillway was designed for preventive measures during hurricanes, floods, and droughts. Report Prepared by: David E. Port and Dena E. Hodes, New South Associates Date: December MOORE HAVEN LOCK, SPILLWAY (Moore Haven Lock, Building No. HAER NO. FL-18-I Page 2 PART I. HISTORICAL INFORMATION A. Physical History: 1. Date of Construction: 2. Architect/Engineer: U.S. Engineer Office, Jacksonville, Florida, War Department 3. Original and Subsequent Owners: State of Florida, U.S. Army Corps of Engineers 4. Original Builder: Murphy Construction Company, West Palm Beach, Florida 5. Alterations and Additions: None B.

Historical Context: This spillway was constructed in in conjunction with the alterations to the spillway at Ortona Lock and Dam and the construction of the Franklin Lock facility near Alva, Florida. This structure was deemed necessary to better facilitate the flow of water from Lake Okeechobee. PART II. DESCRIPTION A. General Statement The Moore Haven Spillway is situated east of the lock in the wall of the levee that surrounds Lake Okeechobee. It is operated for flood control, irrigation, maintenance of water stages during low-flow periods and water conservation during droughts. This structure was built in in conjunction with the construction of the of the W. P. Franklin Lock facility, which was completed in and the renovations to the spillway at the Ortona Lock and Dam.

Combined with severe droughts, floods, and erosion control resulting from large releases of water during the early these modifications and alterations along the Caloosahatchee River were part of a growing awareness to regulate and efficiently govern Lake Okeechobee's water discharge while delegating the water MOORE HAVEN LOCK, SPILLWAY (Moore Haven Lock, Building No. HAER NO. FL-18-I Page 3 management and conservation strategies of the Central and Southern Flood Control District. The concrete spillway has four bays consisting of four vertical or slide gates. There is a control house attached to the spillway on its west, upper side. B.

Physical Description Moore Haven Spillway This reinforced concrete structure consists of four vertical lift or slide gates, which are essentially horizontal sheets of steel that are commonly designed to impede and dam lake waters. The spillway assembly is constructed on a poured reinforced concrete foundation set at least 6' into the canal bottom. The slide gates and the four bays of the spillway are housed in an open two-story poured reinforced concrete structure. The second story of this structure is a bridge that houses the hoists and is known as the operating platform. The lower platform below the bridge consists of the walkway connecting the east shore of the Caloosahatchee Canal to the island that divides the lock chamber and spillway.

The existing structure rises above the normal pool level. Vertical Lift Gates The four gates measure x Each gate is raised and lowered by a double two-part wire rope block and tackle arrangement with the lead line end of the two ropes attached to the top of the gate. The double-sheave-block crosshead assembly is directly connected to the piston rod of the actuating horizontal trunnion-mounted hydraulic cylinder. Thus, the movement of this piston with the double-block effects movement of the gate in a ratio of 1 to 2 respectively. The hoist cylinders are actuated by a packaged hydraulic power and control unit located in the operator's house with pressure and return lines to the hoist units of the spillway.

The flow control valve for each hoist unit is adjusted to regulate the gate speed to 6" per minute regardless of the load. Lowering of the gates must be achieved (by gravity) without operation of the power unit, by proper positioning the directional control valve. An engraved laminated bakelite label MOORE HAVEN LOCK, SPILLWAY (Moore Haven Lock, Building No. HAER NO. FL-18-I Page 4 is located adjacent to the directional control valve showing the position of the valve handle for the "Raise," uHold" and "Lower" operation. Cable slings are provided (two for each gate) as a means of supporting the gate at the full open position, independent of the hoist proper for servicing or replacing of hoist cables.

The spillway's maximum discharge designed for flood capacity is Cubic Feet per Second The vertical slide gates are equipped with vertical and horizontal seals. The gates seal by way of a heavy-duty rubber bumper that effectively prevents water leakage when closed. The seals are constructed of hard rubber with a tire tread core and are attached to the gates by corrosion-resisting steel bolts. These seals are also called baffle seals, which impede the force of water when the gates are opened, thereby slowing discharge and possible water erosion damage.

Vertical Gates' Mechanical Equipment This power unit consists of a fluid pump driven by an electric motor, a solenoid operated unloading valve, a pressure gauge, an emergency hand pump and a relief valve, all mounted on a 60 gallon oil reservoir with stand and drip pan. The motor for driving the fluid pump is rated 220 volt, 3 phase, 60 cycle. Also located in the control house on a shelf above the stilling wells is a dual water level recorder for recording upstream and downstream water levels. Each gate is manually controlled from a pushbutton station mounted on the frame of the hoist unit at the center of each gate bay. Gates are raised by hydraulic pressure from the power unit while being lowered by gravity only.

A separate manually adjustable hydraulic flow control valve for regulating the speed of each gate individually is located on the valve panel of the hydraulic power unit. The valve for each gate is adjusted to a speed of approximately 6" per minute with a hoist load of pounds and an operating pressure of PSI while raising the gates with an unbalanced head of MOORE HAVEN LOCK, SPILLWAY (Moore Haven Lock, Building No. HAER NO. FL-18-I Page 5 Spillway Operator's House The spillway operator's house is cantilevered on the western end of the spillway adjacent to the western pier of the spillway's operating platform bridge.

It is a one-room, flat roof, reinforced concrete structure measuring x x On the north and east side of the operator's house, the building's walls are flush with the spillway structure. On the north exterior, a concrete buttress known as the stilling well and resembling an exterior end chimney descends down the height of the building at its midpoint. Tapered ends slope to meet the roof and spillway's exterior wall on the top and bottom of this buttress. This protrusion measures x x approximately 10' and functions as a rectilinear concrete sheath to partially cover the pipe that carries the hydraulic oil from the pump motor, which powers the spillway's vertical lift gates, out of the building.

Concrete covered electrical trenches extend from the operator's house along the length of the spillway's lower walking platform. The spillway operator's house is accessed on the west elevation via a half-glass, steel door measuring x The structure contains one fixed three-over-three sash window facing west and measuring x and one fixed two-over-two sash window facing north measuring x The interior of the spillway operator's house consists of a single room with no architectural details. The room houses the electrical panel and hydraulic pump that controls the raising and lowering of vertical lift gates and operates the spillway's lighting. C. General Siting and Orientation The spillway is situated east of the lock chamber within the levee that surrounds Lake Okeechobee.

A manmade island separates the lock and spillway. The spillway is accessed by walkways located on the top of the levee. PART III. ENGINEERING DRAWINGS The engineering drawings are located at the U.S. Corps of Engineers Office, South Florida Office, Clewiston District. They MOORE HAVEN LOCK, SPILLWAY (Moore Haven Lock, Building No. HAER NO. FL-18-I Page 6 have been electronically scanned producing high-resolution images. The full collection of scanned images for Ortona Lock and Dam will be donated to the Florida State Archives, Tallahassee, Florida.

In context

Moore Haven, Florida The place record: every map, photograph and survey of this town.
Glades County, Florida 47 topographic sheets across the county.
Library of Congress record The original filed report as the survey filed it.

Also surveyed in Moore Haven

9 records

The federal surveyors worked through Moore Haven building by building. These are the other structures they measured and filed a report on, longest report first.

SheetStructure SurveyReport
Moore Haven LockHAER FL-1811,189 words
Moore Haven LockHAER FL-18-A2,726 words
Moore Haven LockHAER FL-18-D2,480 words
Moore Haven LockHAER FL-18-C2,402 words
Moore Haven LockHAER FL-18-E1,911 words
Moore Haven LockHAER FL-18-B1,378 words
Moore Haven LockHAER FL-18-F966 words
Moore Haven LockHAER FL-18-G730 words
Moore Haven LockHAER FL-18-H473 words

Provenance

  • Written history. Quoted verbatim from HAER FL-18-I. United States federal work, no copyright under 17 U.S.C. 105.
  • Text capture. Machine-read from the scanned typescript filed with the survey, so spelling and spacing follow the original page.
  • How this page is made. Documentary passages are quoted from the linked federal record; page labels and counts are clearly marked as site presentation or calculations.