See Building 001 Record ROCKETDYNE MANUFACTURING FACILITY, BUILDING 035 HAER No. CA-2355-L (Page 2) Part I. Historical Information A. Physical History: 1. Date(s) of construction: January 29, 2. Architect/Engineer: Rocketdyne Plant Engineering 3. Builder, contractor, suppliers: Rocketdyne Plant Engineering 4. Original plans and construction: None 5. Alterations and additions: Steel doors added to exterior in Earthquake Safety B. Historical Context: See Building 001 Record Part II. Architectural and Structural/Design/Equipment Information A. General Statement: 1. Character: The Paint and Chemical Storage structure (Building is located near the southwest corner of the complex, perpendicular to Building 29.
Building 035 is a large single-story utilitarian prefabricated metal warehouse-like structure with a pitched roof. Building 035 s distinguishing features include its oversized metal double-doors at the east end of the north and south elevations, and the large open sections along the north and south elevations providing access to stored items. The large openings occupy more than half of the Building s north and south elevations and are covered by plastic strip curtain doors. The interior space is separated into three sections with concrete-slab floors separated by plaster walls. Two of the bays are accessed via oversized double- doors, while the third, and largest, bay is enclosed with plastic strip curtain doors.
The ceilings are made up of exposed corrugated steel supported by metal trusses, brackets, and rafters. Industrial lighting is provided by suspended light fixtures. 2. Condition of fabric: Despite some of the paint peeling from the ceiling and walls, Building 035 appears to be in good condition with no major indications of deterioration. B. Description of Exterior: 1. Overall dimensions: Building 035 is a rectangular building with overall dimensions of approximately 120 long by 50 wide. The building is approximately square feet. ROCKETDYNE MANUFACTURING FACILITY, BUILDING 035 HAER No. CA-2355-L (Page 3) 2. Foundations: Building 035 sits on a reinforced concrete foundation. 3. Walls: The exterior walls consist of prefabricated corrugated steel sheathing and horizontal wood siding. 4.
Structural system, framing: Building 035 s structural system consists of a prefabricated steel frame attached to corrugated steel sheathing and steel girders and beams. 5. Openings: a. Doorways and doors: Building 035 has two sets of oversized door openings on the east end of the south and north elevations. Each opening contains a pair of heavy steel doors. The doors were changed in Also along the north and south elevations are large openings enclosed with plastic strip curtain doors. There are no other doors on the exterior of Building 6. Roof: a. Shape, covering: Building 035 has a low sloping pitched roof with a corrugated steel surface. b. Cornice, eaves: Building 035 has overhanging eaves with no exposed rafters. c.
Dormers, cupolas, towers, clerestories, monitors: Roof-top ventilators are evenly spaced along the Building s roof. C. Description of Interior: 1. Floor plans: Building is a rectangular shaped structure, broken up into six bays of equal size. The four bays on the west end of the building make up a single open storage space filled with metal frame shelves. The two remaining bays are fully enclosed. The Dispensing Room contains multiple metal shelves and has steel double doors leading to the exterior at both ends. The eastern-most bay is divided into two spaces by a 12 metal bulkhead. The south end of this bay is used to store chemicals, while the north end is used for acid storage. 2. Stairways: None 3. Flooring: The floors throughout Building 035 are concrete. 4.
Wall and ceiling finish: Walls throughout Building 035 are composed of exposed siding, except in the dispensing room where the walls are finished with plaster. The ceiling is finished with exposed sheathing throughout the Building. 5. Openings: a. Doorways and doors: There is only one interior door in Building The door connects the dispensing room with the open storage area and consists of ROCKETDYNE MANUFACTURING FACILITY, BUILDING 035 HAER No. CA-2355-L (Page 4) a single sliding door. A note in the historic building plans state that all exits must be openable from the inside without a key. 6. Mechanical equipment: a. Heating, air conditioning, ventilation: Building 035 was used to store paint and chemicals; therefore, ventilation was an obvious necessity.
Multiple ventilators occupy the roof of Building The open storage area utilized four rotary ventilators, while the acid and chemical storerooms utilized a single rotary vent made by the Western Engineering and Manufacturing Company. The dispensing room has a single DeVilbiss exhaust fan with a 90-degree weatherproof elbow and bird screen. b. Lighting: Lighting in Building 035 consists of multiple warehouse halogen high bay lights. Part III. Operations and Process A. Operations: Building 035 was used for paint and chemical storage. Part IV. Sources of Information A. Primary