BlockBefore

St. Lucie Canal, Lock No. 1, Attendant's Quarters, St. Lucie, Cross State Canal, Okeechobee Intracoastal Waterway, Stuart (HAER FL-20-A-5)

St. Lucie Canal, Lock No. 1, Attendant's Quarters, St. Lucie, Cross State Canal, Okeechobee Intracoastal Waterway, Stuart, Martin County, FL. Surveyed as HAER FL-20-A-5, with a 1,255-word written history.

From the record

“The attendants quarters were essential to the successful operation of the lock and dam.”

Written record, HAER FL-20-A-5 survey. Machine-read text.

Surveyed by the federal HAER program as HAER FL-20-A-5 · the record runs 1255 words · one of 10 surveyed structures published for this county.

Sources: the survey record at the Library of Congress

Significance

1126 words

The headings the report itself prints. Each one jumps to where it begins.

Source document Quoted word for word from HAER FL-20-A-5. Not written, edited or summarised by this site.

The attendants quarters were essential to the successful operation of the lock and dam. Their presence allowed the continual operation and maintenance of the facility. Report Prepared by: David E. Port and Dena E. Hodes, New South Associates Date: December ST. LUCIE CANAL, LOCK NO. 1,

Attendant's Quarters

Lucie Canal, Lock No. 1, Single House B) HAER NO. FL-20-A-5 Page 2 Part I. Historical Information A. Physical History: 1. Date of construction: 2. Architect/Engineer: U.S. Engineer Office, Jacksonville, Florida 3. Original and subsequent owners: State of Florida, U.S. Corps of Engineers 4. Original Builder, Contractor, Supplier: Cleary Brothers Construction Company, West Palm Beach 5. Alterations and Additions: These buildings are fairly intact with some alterations of the original fenestration, i.e., replacement windows and garage converted into living space. Porches and prefabricated metal carports were also added. B. Historical Context In Congress authorized replacing the era St. Lucie Lock No.

1 with a weir at Port Mayaca and adding a larger lock and spillway to the existing lock on the eastern end of the canal or at Lock No. 2. During this year, the St. Lucie Canal was also widened and deepened, and the cost for this pre-War last installment of the Cross-State Canal was earmarked at In May plans were completed for the new lock and central control station, which included a hydroelectric power plant and a spillway dam to be built as a replacement lock at the original Lock No. 2 site. Quarters were constructed to house the attendants and their families. Five quarters were clustered east of the lock and dam system in a residential area.

One of the homes was set to the side, presumably the residence of the lockmaster, while the remaining were sited in pairs, two on the access road opposite one another, and a second pair to the south that faced the water. Four of these residences were constructed using a standardized plan named Single House B. ST. LUCIE CANAL, LOCK NO. 1, ATTENDANT'S QUARTERS Lucie Canal, Lock No. 1, Single House B) HAER NO. FL-20-A-5 Page 3 PART II. DESCRIPTION A. General Statement The four Attendant's Quarters Single House B plan residences were constructed to house lock personnel in All of the four attendants' houses are L-shaped, two bedroom, concrete block ranch style houses. They are currently privately owned and are used as residences. Two quarters oppose one another on the entry road.

The remaining set is located to the south where they face the canal. The set on the canal side possesses reversed layouts for privacy. B. Physical Description 1. Exterior a. Overall dimension, and exterior treatment: The four one-story four-bay-by-two-bay Single Houses Plan B house type measures x x to the roofline. The house has a main lateral fable roof and a gable over the front ell. Interior and exterior design appointments for the Single House B houses are similar, including the use of brick windows and door surrounds, painted stucco covering the concrete block walls original steel storm awnings, and the clay pipe employed selectively below the eaves to vent the roof.

Exterior treatment included decorative brick trim around window and door surrounds, 4" clay pipe vents, original steel storm awnings, and copper-mesh screen for the screened porch. The roof was asbestos-cement shingle with copper flashing about the chimney and with copper downspouts. The exterior was painted stucco over concrete blocks. 2. Interior a. Floor plan: Though slightly smaller in design than the Single House Plan A house type, they contained a centrally located living area and dining room kitchen, two bedrooms, and a bath. The bedrooms and bath are located on one end of the house while the communal spaces were grouped at the other. The main entry was accessed from the screen porch that is part of the front facing ell. The Single Houses B were designed to provide a ST.

LUCIE CANAL, LOCK NO. 1, ATTENDANT'S QUARTERS Lucie Canal, Lock No. 1, Single House B) HAER NO. FL-20-A-5 Page 4 spacious living room entered exclusively from the screened porch. The garage abuts the end of the living room. The bedrooms of the B Plan are sized and arranged somewhat differently giving the impression that one would serve as the master bedroom. The larger bedroom is x and the smaller is x The larger closet is located in the smaller bedroom. The bathroom is laid out similarly as the houses in Plan A. This arrangement produces a slightly more linear hallway connecting the two rooms. Unlike Plan A, the screened porch at this location can only be entered through the porch door and the living room. The kitchen is laid out with access via both the dining room and the garage.

The overall plan features a walk-through with the sink and steel cabinets aligned along the rear wall. The garage width is narrower by 2' in these models, but it runs the full of the house thereby providing greater storage capacity. The living room's fireplace hearth foundation intrudes slightly into the garage floor space. b. Wall and ceiling finishes, doors, and floors: The interior treatment of the both the Single House Plan A and Houses Plan B included gypsum wallboard on 2" x 4" stud walls and painted plaster block on all exterior walls. Sash type windows and four door styles rounded out these nicely appointed designs. Interior bedroom door featured fixed-louver, full-length panels while the door from the screened porch to the living room featured a one-over-five glazed full panel.

Closet, bathroom, and other interior doors featured a full-length, unglazed fir panel. The living, dining, and bedroom floors were specified as oak. Kitchen floors were linoleum, while the bathroom was asbestos tile. The bathroom also featured an asbestos wainscoting extending from the floor. Walls were left unfinished in the garage, and the screened porch contained concrete floors. C. General Siting, Orientation and Landscape The Attendants Quarters were set in a residential cluster paralleling the canal and lock. The quarters were laid out in sets with one opposing pair on the entry road and the second set facing the canal to the south. The Lock master's residence was placed to the north; its separation allowing greater privacy. ST. LUCIE CANAL, LOCK NO.

1, ATTENDANT'S QUARTERS Lucie Canal, Lock No. 1, Single House B) HAER NO. FL-20-A-5 Page 5 Lawns typically surround each of the quarters with some foundation plantings in the front of some of the buildings and palms. PART III. SOURCES OF INFORMATION A. Architectural Drawings Two as-built drawings for St. Lucie Lock No. 1 Attendant's Quarters Single House B were identified within the engineering drawing collection for the St. Lucie Lock and Dam complex at the U.S. Corps of Engineers Office, South Florida Operations Office, Clewiston District. Both drawings have been photocopied.

In context

Stuart, Florida The place record: every map, photograph and survey of this town.
Martin County, Florida 78 topographic sheets across the county.
Library of Congress record The original filed report as the survey filed it.

Also surveyed in Stuart

9 records

The federal surveyors worked through Stuart building by building. These are the other structures they measured and filed a report on, longest report first.

SheetStructure SurveyReport
St. Lucie CanalHAER FL-2012,389 words
St. Lucie CanalHAER FL-20-A5,357 words
St. Lucie CanalHAER FL-20-A-32,406 words
St. Lucie CanalHAER FL-20-A-12,383 words
St. Lucie CanalHAER FL-20-B1,222 words
St. Lucie CanalHAER FL-20-A-21,201 words
St. Lucie CanalHAER FL-20-A-41,144 words
St. Lucie CanalHAER FL-20-B-11,029 words
St. Lucie CanalHAER FL-20-B-2788 words

Provenance

  • Written history. Quoted verbatim from HAER FL-20-A-5. United States federal work, no copyright under 17 U.S.C. 105.
  • Text capture. Machine-read from the scanned typescript filed with the survey, so spelling and spacing follow the original page.
  • How this page is made. Documentary passages are quoted from the linked federal record; page labels and counts are clearly marked as site presentation or calculations.